Page 13 of 29 FirstFirst ... 3 11 12 13 14 15 23 ... LastLast
Results 145 to 156 of 347

Thread: Eclipse step by step

  1. #145
    thanx good thread

  2. # ADS
    Spons Circuit
    Join Date
    Always
    Posts
    Many
     
  3. Quote Originally Posted by vinomarky View Post
    If the input files are not too big, upload them somewhere, send me a pm with the location and I'll take a look at it
    I'm sorry Sir, I can't do that. this is confidential data.

    do you have any suggestion to correct/check my models?

    what the minimum keyword i have to use in PVT Sir?

  4.    Sponsored Links



    -

  5. Quote Originally Posted by vinomarky View Post
    Not possible to produce more than is in place.. Eclipse does these sorts of checks quite well

    Some thoughts - are you comparing FGPT to GIIP in reservoir conditions or standard conditions?

    Are you gas injecting?


    I'm sure there's a reasonable answer.
    i had been comparing FGPT to OGIIP in same condition sir.
    Last edited by acang_024; 06-15-2010 at 03:34 PM.

  6. eclipse to petrel error

    Dear All
    I convert a eclipse run to petrel case (Prediction up to 2040)
    but when I want to use related property for example SGAS 2021 in calculator there is syntax error related to number of realization and restard.
    Please help me in this matter.
    Regards.

  7. #149

    Join Date
    Nov 2008
    Location
    Australia
    Posts
    508
    First - please don't call me sir... makes me feel old ;-)

    Second - without looking at the deck, I don't think I can help you any further. If the sum of SUMMARY data FGIP + FGPT changes with time without any external gas supplement, then something is significantly awry and I suggest you contact your local SLB support staff to help sort out.

  8.    Spons.


  9. Quote Originally Posted by vinomarky View Post
    First - please don't call me sir... makes me feel old ;-)

    Second - without looking at the deck, I don't think I can help you any further. If the sum of SUMMARY data FGIP + FGPT changes with time without any external gas supplement, then something is significantly awry and I suggest you contact your local SLB support staff to help sort out.
    is it a must to use SEPCOND and WSEPCOND when we run eclipse e300 ?

  10. in my models i found that pressure increase by time goes on,whereas no injection well and no aquifer , what the keyword is wrong? (i use e300 for gas reservoir simulation)

    please help me. thanks alot

  11. #152

    Join Date
    Nov 2008
    Location
    Australia
    Posts
    508
    I take it that this is the same model that has GIIP increasing over time correct?

    Despite what you may believe about no injection wells/aquifer etc currently in your deck, it is clear that you DO have something introducing gas into your system - Eclipse does not simply add gas to a system without instructions.

    There is no special keyword to 'solve' this - you have (inadvertently I grant) specified some keyword(s) that is currently adding gas to the system - without posting your deck for us to look at (even just the SOLUTION & SCHEDULE sections would probably cover where the error is) there is little chance any of us is going to be able to help spot the problem.
    Last edited by vinomarky; 06-20-2010 at 10:49 AM.

  12. Quote Originally Posted by temr View Post
    Please find the presentation below it is short and give you general overview how to make j function
    which do you prefer Sw map generate by petrophisic or J-laverrate ?

  13. #154

    Join Date
    Nov 2008
    Location
    Australia
    Posts
    508
    Assuming you believe your petrophysics, I usually prefer to tune a saturation function (j func or other) to honour the petro and/or scal and initialize with the function. Petro maps, while potentially appropriate at wells suffer due to making simple interpolation in between wells - not necessarily honoring property (perm/poro) specific saturation trends

  14. by question that Mr. temr has ever send (page 12 in this thread) how calculate SW by J-laverate, there is H (distance WOC and grid), how do u get WOC? because i don't have RFT. do u use petrephysic data to get LKO/WOC?

  15.    Spons.


  16. #156

    Join Date
    Jan 2009
    Location
    ALA, KZ
    Posts
    436
    Use data from well tests fro position of you Owc

Similar Threads

  1. Replies: 11
    Last Post: 07-31-2016, 04:02 AM
  2. Eclipse Step by Step?
    By Zuper in forum Reservoir
    Replies: 2
    Last Post: 04-05-2012, 12:56 AM
  3. Step by step to calculate control valve Cv thorugh Intools
    By hswang2 in forum Instrumentation & Control
    Replies: 1
    Last Post: 11-28-2010, 09:37 AM

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40