Page 12 of 29 FirstFirst ... 2 10 11 12 13 14 22 ... LastLast
Results 133 to 144 of 347

Thread: Eclipse step by step

  1. #133

    Join Date
    Jan 2009
    Location
    ALA, KZ
    Posts
    436
    Quote Originally Posted by acang_024 View Post
    Mr. temr, do u have any suggestion to solve history matching faster?
    There is no solution to do this.
    The only thing is that you need to be shure on you input data like
    1. Well log data
    2. Well test data
    3. Scal data
    4. Production data
    5. Pressure data

  2. # ADS
    Spons Circuit
    Join Date
    Always
    Location
    Advertising world
    Posts
    Many
     
  3. --Warning
    Bottom hole pressure limit not set for well SB-D22
    Will use default value of 1469.590 Psia

    i set GRAT and THP on WCONPROD, i use e300. i got warning like above.

    what should i do, i wanna make GRAT constant at 2500 mmscf/day, the simulator automatically set BHP at 1469.590 psi (i thought this is a default number), it make decrease GRAT.

  4.    Sponsored Links



    -

  5. #135

    Join Date
    Jan 2009
    Location
    ALA, KZ
    Posts
    436
    For simulator to back calculate bhp from thp you need to provide to him VFPi table
    try this
    WCONPROD
    Well OPEN GRAT 2* 2500 1* 1* 145 10* /

  6. Mr. term i got trouble when i run e300.

    the message

    " Zero determinant problem in LAINV(n)"

    after that run stop suddenly.

    what should i do sir.

  7. dear Mr. term

    i would like to ask a question. i got 2 number FIP on initialization (E300) the 1st is GAS wrt separator (mscf) and the 2nd is Gas Res Vol (rb) which one i have to use on initialization step?

    and then, when i forecast my reservoir model(gas reservoir). after 20 years, the cumulative gas production is bigger than number on FIP (Gas wrt separator), so the recovery factor is more than 100 %, very very impossible, what wrong with my models

    thanks a lot

  8.    Spons.


  9. #138

    Join Date
    Jan 2009
    Location
    ALA, KZ
    Posts
    436
    Sorry i am not expert in 300 look in manual

  10. #139

    Join Date
    Nov 2008
    Location
    Australia
    Posts
    508
    Not possible to produce more than is in place.. Eclipse does these sorts of checks quite well

    Some thoughts - are you comparing FGPT to GIIP in reservoir conditions or standard conditions?

    Are you gas injecting?

    I'm sure there's a reasonable answer.

  11. Yes, i'm comparing FGPT and GIIP base on FIP calculation on initialization (GAS wrt (separator) both fip and GIIP on MSCF. there's no gas injection well. i'm confuse how to calculate recovery factor of this filed after 20 years forecast.

    thanks a lot Mr.

  12. #141

    Join Date
    Nov 2008
    Location
    Australia
    Posts
    508
    1. Add FGIP to your SUMMARY section
    2. Run
    3. Plot and answer your own question... Very much doubt that it will increase with time.. If it does you have something funky going on like gas injection that you are not aware of

  13. Thanks Sir, i'll try your suggestion

  14. FGIP decrease by time goes on, but if i plot together with FGPT, FGIP initial < FGPT (end of forecast), and I'm sure that no injection gas well.

  15.    Spons.


  16. #144

    Join Date
    Nov 2008
    Location
    Australia
    Posts
    508
    If the input files are not too big, upload them somewhere, send me a pm with the location and I'll take a look at it

Similar Threads

  1. Replies: 11
    Last Post: 07-31-2016, 04:02 AM
  2. Eclipse Step by Step?
    By Zuper in forum Reservoir
    Replies: 2
    Last Post: 04-05-2012, 12:56 AM
  3. Step by step to calculate control valve Cv thorugh Intools
    By hswang2 in forum Instrumentation & Control
    Replies: 1
    Last Post: 11-28-2010, 09:37 AM

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40