Thread: HTRI learning - Question and Answers

  1. #61
    Air cooled HX uses "cool air" which is at ambient temperature to cool th process fluid. Obiviously the outlet temp which is less than the air temperature cannot b chieved . For this anothe shell & tube HX at the tail end will be required osing cold water

  2. # ADS
    Spons Circuit
    Join Date
    Always
    Location
    Advertising world
    Posts
    Many
     
  3. #62
    Thermal resistance calcultions are the same used for calculating over-all heat transfer coefficient using the fluid property and conductivity etc.
    % under design mans that the total heat transfer calculated by the programme is less than the design ' desired heat transfer .
    For achieving over design u have to change the parameters of the HX, like number of passes, lengt of tubes, number of tubes etc.

  4.    Sponsored Links



    -

  5. #63
    Quote Originally Posted by biswjeet View Post
    can anyone gives me following ( related to HTRI)

    what is thermal resistance calculations ?
    % underdesign , how to make it overdesign
    Thermal Resistance means the resistance offered by various elements to heat flow.
    In case of exchanger, the elements are metal wall of tube, fouling layer and geometric & transport parameters of the shell side and tube side.
    Under design means the amount by which the exchanger is falling short of its desired performance/capacity.
    A exchanger with an under design parameters can be overdesigned either by changing the geometric parameters like tube thk, tube od, shell id, baffle spacing, etc. or in some case by increasing the mass flowrates of shell side and tube side fluids

  6. #64
    Quote Originally Posted by biswjeet View Post
    what is thermal resistance calculations ?
    % underdesign , how to make it overdesign
    The thermal resistance in the output summery is percent of the total thermal resistance.

    Overdesign: This value is based on specified duty if input, on calculated duty if duty not input. Overdesign is calculated as follows:
    % Over design = 100(Uo /Ureq –1)

    If you make the size (area) bigger or higher velocity will help to get overdesign, or you may need to optimize say the baffles.
    You may start to play with one of the examples.

  7. Htri

    Thanks everybody for the help foe my querries

    can anyone gives me following

    is over surface % = over design % in HTRI

    PLS SPECIFY N DETAIL

  8.    Spons.


  9. HTRI- VMG Thermo Property

    HTRI- VMG Thermo Property error

    hi everybody

    in HTRI , i cannot able to create VMG Thermo property .

    ERROR- VMG Thermo Package Authorization failed

    is their requirement of cr*a*ck file of VMG Thermo property , like other .dll files
    can anyone give me solution please

    if any other problem , please give solution

  10. #67
    Quote Originally Posted by biswjeet View Post
    in HTRI , i cannot able to create VMG Thermo property .

    ERROR- VMG Thermo Package Authorization failed

    is their requirement of cr*a*ck file of VMG Thermo property , like other .dll files
    can anyone give me solution please

    if any other problem , please give solution
    I just try the VMG property, and I got no error. I am not using VMG normally.
    So it seems not always to be problems on authorization, and from the text on this page it should be include in the normal pack.

    [link Point to another website Only the registered members can access]
    Could you up-load the HTRI case file you are working on - or more detail needed.


  11. Htri--- rating ---design

    Can anyone tel me

    how to start with HTRI rating, i mean from start to finish

    if requirement is of over design , then go for increasing tube s or shell id ? or any other parameter

    where to stop rating ( satisfactorily calculations )

    at which stage to start design

    please explain with example --- if possible

  12. #69
    Hello!
    Dear frends, can someone guide me with a dilema: Is the face velocity for an aircooler too low( 1 m/s) ? What is the lowest limit to consider?
    Thanks a lot for your help!
    Best regards!

  13. #70
    All,

    I'm new to HTRI and have faced a warning message: "Setting plan error: Convergence problem during baffle check. Calculations terminated in routine BXPASS". It's a warning message so HTRI still runs to give the final output. I understand that there may be something wrong with the baffle spacing and/or baffle cut that leads to the warning message but don't understand why. I also searched for the word "BXPASS" in HTRI help but it returned no match. For detail (TEMA type, baffle info ...) please refer to the file attached. Please help explain the message and advise if it makes the design result unreliable.

    Thank you.
    Attached Files Attached Files

  14. #71
    Quote Originally Posted by vne View Post
    "Setting plan error: Convergence problem during baffle check. Calculations terminated in routine BXPASS". It's a warning message so HTRI still runs to give the final output. I understand that there may be something wrong with the baffle spacing and/or baffle cut that leads to the warning message but don't understand why. I also searched for the word "BXPASS" in HTRI help but it returned no match. For detail (TEMA type, baffle info ...) please refer to the file attached. Please help explain the message and advise if it makes the design result unreliable.
    Out from the drawing in the sheet I can't see how your baffles could work - they are only in the center? Please upload the HTRI-file.

  15.    Spons.


  16. #72
    Quote Originally Posted by biswjeet View Post
    Can anyone tel me

    how to start with HTRI rating, i mean from start to finish

    if requirement is of over design , then go for increasing tube s or shell id ? or any other parameter

    where to stop rating ( satisfactorily calculations )

    at which stage to start design

    please explain with example --- if possible
    Biswajeet,
    In rating mode,
    User shall specify most of the geometry and program shall then Rate the geometry and describe the expected performance.
    To stop : One will check for
    Pressure drops on tube and shell side are within desired limits
    and area provided vs area required
    If provided is more than required it is overdesign.
    Now how much more. If one has experience with given exchagner and if he is sure that whaever streams he is handling are not going to change and that the fouling is adequately considered then even 1-2 % OD is also ok. If not then one has to ocer design by more if felt necessary for process

  •   

Similar Threads

  1. NEBOSH International Diploma Past Exams Question and Answers
    By nayakya in forum Safety And Environment
    Replies: 19
    Last Post: 07-26-2018, 07:27 AM
  2. Where Can I find Piping design question & answers?
    By Antony in forum Oil And Gas Production
    Replies: 1
    Last Post: 01-22-2014, 10:56 PM
  3. CSWIP New Question Pattern and Model Question Paper needed.
    By vijay1583 in forum Mechanical Engineering
    Replies: 4
    Last Post: 07-26-2012, 10:35 PM

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •