View RSS Feed

The Best of the Internet

Maximum designed pump efficiency

Rate this Entry
Quote Originally Posted by Esam View Post
A pump does not completely convert the kinetic to pressure energy. Some of the energy is always lost internal and external in the pump.
Internal losses

  • hydraulic losses - disk friction in the impeller, loss due to rapid change in direction an velocities through the pump
  • volumetric losses - internal recirculation at wear rings and bushes

External losses

  • mechanical losses - friction in seals and bearings


The efficiency of the pump at the designed point is normally maximum and is called the

  • Best Efficiency Point - BEP

It is possible to operate the pump at other points than BEP, but the efficiency of the pump will always be lower than BEP.

Submit "Maximum designed pump efficiency" to Digg Submit "Maximum designed pump efficiency" to del.icio.us Submit "Maximum designed pump efficiency" to StumbleUpon Submit "Maximum designed pump efficiency" to Google

Tags: None Add / Edit Tags
Categories
Mechanical