Hello,
I'm trying to repeat hand calculations provided in Pipesim x2007 course manual.
I have a couple of questions. First, the frictional pressure term has wrong physical dimension.
As stated in manual,
[dp/dL] = [f*rho*v^2/(2*g*d)] = M/L^3 * (L/T)^2 / (L/T^2 * L) = M/L^3
As stated in 2nd Newton's law, p = F/S = m*a/S, so
[dp/dL] = M * L/T^2 /L^2 = M/(T^2*L).
Second question, I got result that differ on 3 orders of magnitude from answers printed
in course manual. These numbers marked with red color in my spreadsheet. Could you please
point out what's going wrong in my calculations?
My Spreadsheet
pipesim_v2007_course_manual.pdf
-------------------
Ah, I see now that parameter L should be 20025 ft rather then 20.025 ft.