  • Carbamate leakage from Stripper outlet line

    Hi,

    Our stripper bottom outlet line CS flanges having carbamate/urea at 2350 psig and 380 deg F is leaking. One slip-on flange is of line and other is of Control valve. Leakage is varying from 30 dpm to 250 dpm. More tightening of flanges not possible without damaging titanium gasket. Box-up is not an option as leaking urea will corrode the CS flanges. By applying air, leakage stopped due to carbamate/urea solidification. but as soon as we removed air, leakage started again.

    Plant shutdown is not an option for now. What will be more preferable i.e will less corrode the flanges:
    a) leaking carbamate/urea solution
    b) Solidified carbamate/urea solution
    &
    What will be the extent of crevice corrosion in flanges due to solidified stagnant carbamate/urea?
    This article was originally published in forum thread: Carbamate leakage from Stripper outlet line started by rhameed View original post
    Comments 2 Comments
    1. rawngsula's Avatar
      rawngsula -
      first of all how come your stripper out let line is of CS. CS are not recommended for high pressure and temp urea/carbamate handling. It should be of 316L urea grade. Its really surprising me! Its a very risky operating with urea/carbamate leakage since urea/carbamate are highly corrosive for CS and CS is no where used.
    1. yudh1984's Avatar
      yudh1984 -
      Quote Originally Posted by rawngsula

      [link Point to another website Only the registered members can access]

      first of all how come your stripper out let line is of CS. CS are not recommended for high pressure and temp urea/carbamate handling. It should be of 316L urea grade. Its really surprising me! Its a very risky operating with urea/carbamate leakage since urea/carbamate are highly corrosive for CS and CS is no where used.
      Yes, I'm agree with Rawngsula. SS 316L urea grade, 25Cr22Ni2Mo, 22Cr5Ni duplex, Ti and Zr are used as construction or lining materials in the synthesis equipment. Ammonium carbamate solutions in contact with carbon steel will cause corrosion rates in excess of 900 mmpy. Carbamate in carbon steel in urea synthesis can lead to catastrophic failures.
  • .

  • Recent Threads

    brom

    latest TOTAL electrical specifications

    Thread Starter: brom

    Hi
    Please share latest electrical specs of TOTAL issued after 2020.
    Thanks

    Last Post By: brom 06-06-2026, 09:57 PM Go to last post
    vilas019hn

    Girls In Your Town - No Selfie - Anonymous Casual Dating

    Thread Starter: vilas019hn

    Private Girls From Your City - No Selfie - Anonymous Casual Dating
    https://privatedates.life

    Private Girls From Your City -

    Last Post By: vilas019hn 06-06-2026, 03:19 AM Go to last post
  • Recent Activity

    popov_al

    ASME collection

    Thread Starter: popov_al

    Last Post By: popov_al Yesterday, 09:33 PM Go to last post
    anhthoichoem

    Astm series full

    Thread Starter: anhthoichoem

    Last Post By: popov_al Yesterday, 09:31 PM Go to last post
    popov_al

    IEC collection

    Thread Starter: popov_al

    Last Post By: popov_al Yesterday, 09:30 PM Go to last post
  • .

  • ..