  • Ecrin Sapire input data

    Quote Originally Posted by zaheer.jamali View Post
    im confused in input of
    Net thickness of reservoir
    i have net perforated interval and gross
    can i put net perforated interval in the place of net thickness of reservoir
    at the first step of ecrin sapire well test software


    Dear friend
    my advice is to use the effective length, which mean the length of the perforation which is active (contributing). You have to take a look at PLT
    survey if it is available. Be careful the h value will have an enormous effect on your permeability.
    This article was originally published in forum thread: Ecrin Sapire input data started by zaheer.jamali View original post
  • .