  • saturation in simulation

    hello everybody,
    i have one question regarding the basic concept of water saturation and its use in reservoir simulation. in literature we deal with two types of water saturation. connate water saturation and irreducible water saturation. connate water saturation is developed during the initial phase of migration. if connate water saturation is less than irreducible saturation, water is not movable. (please correct me if i am wrong).
    now during my gas reservoir simulation, i only have SWL (connate water saturation) and relative permeability SGWFN data. i set a value of 0.2 and .1 for my critical water saturation SWCR and critical gas saturation(SGFR) values respectively. i set a maximum connate water saturation value to .8 . now when i run my simulation its showing error messages like this

    CONSISTENCY PROBLEM WITH WATER PHASE END POINTS IN GRID CELL ( 6, 32, 1 ) CONNATE= 0.8000 CRIT= 0.2000 MAX= 1.0000

    but if i copy SWL for SWCR, its running without error. now i am confused. is it something like that the SWL values are treated as irreducible values? observed production data show that water is produced with gas from the very beginning of gas production. if SWL and SWCR values are same, how can i get water production from the beginning? should i use any keywords like SWAT or SWATINIT to define initial saturations? should these data be diffrerent from SWL data? and if so, what to do as i dont have any other data?

    please help me to solve my problem
    This article was originally published in forum thread: saturation in simulation started by tinni View original post
  • .

  • Recent Threads

    zaohnpittoz8490

    jumper connection

    Thread Starter: zaohnpittoz8490

    jumper handled my ethereum to starting-point transmit to a diverse wallet smoothly, posted my bridge with jumper notes here.

    Last Post By: zaohnpittoz8490 Yesterday, 12:41 AM Go to last post
    brom

    Book

    Thread Starter: brom

    Please share
    Safety of electrical installations up to 1000 Volts
    Rudolph, Wilhelm
    Thanks

    Last Post By: brom Yesterday, 12:39 AM Go to last post
    imp

    API RP 1192 1st (2025)

    Thread Starter: imp

    Please, Can anyone share this API?
    Thanks

    Last Post By: imp 07-14-2026, 11:35 PM Go to last post
  • Recent Activity

    ultima

    Geosoft Oasis Montaj 8.3.1!!!!

    Thread Starter: ultima

    Last Post By: Maung Maung Tun Today, 07:33 AM Go to last post
    nicers

    Ses cdegs 20.0

    Thread Starter: nicers

    Last Post By: ds1lqq Today, 04:49 AM Go to last post
    imp

    Asme b16.5-2025

    Thread Starter: imp

    Last Post By: eddiem Yesterday, 01:48 PM Go to last post
  • .

  • ..

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40