  • Tank Venting Calculations

    hello,everybody:
    how to select the wetted surface of a low-pressure storage tank when itself catches a fire rather than it is exposed to a pool fire ?
    when we calculate the fire water demand or tank breathing valve's venting capacity of a low-pressure storage tank with PV valves on the roof,we will decide the wetted surface of the tank.but in all of the standards or handbook,such as API RP 521,API 2000,they say:the up-limit of the wetted surface normally is 25 feet(required in API RP 521-1999 clause 3.15), or 30 feet(required in API 2000) ,the part which is higher than that up-limit may not be protected or may be not calculated when calculating the breathing valve's venting capacity.All of the up-limits are based on the assumption that the tank are exposed to an outside fire or pool fire,the pool fire's flame can not impinge higher than that up-limit.
    We ignore the conflict of the value(25 or 30 feet) of different standards,we talk about why all of the standards consider the up-limit based on the assumption that the tank are exposed to an outside fire or pool fire(it means to calculate the venting capacity of adjacent tank rather than buring tank)?why not consider the burning tank itself?if a low-pressure storage tank catches a fire at its low-low level,and this tank's height is higher than 30 feet ,how to select its wetted surface when calculating breathing valve's venting capacity?
    in API 2000,table 3B footnote a,it says"Engineering judgment is to be used in evaluating the portion of the area exposed to fire."
    so,for the buring tank,the whole tank height shall be considered.
    but,why all of the standards consider the tank venting capacity based on the assumption of exposing to a pool fire?why not consider the buring tanks' venting?
    This article was originally published in forum thread: Tank Venting Calculations started by taoxianwen123 View original post
  • .

  • Recent Threads

    hopeful

    PVsyst-8.1.0

    Thread Starter: hopeful

    Hello engineering community,
    I would like to exchange PVsyst-8.1.0 for etap 24.0.3

    Last Post By: hopeful Yesterday, 08:11 PM Go to last post
    Techman123

    Api 688 2023

    Thread Starter: Techman123

    Please share. Thank you.

    Last Post By: Techman123 04-14-2026, 05:20 PM Go to last post
    nicers

    PVsyst 8.0.21, DEHNsupport 3.251, Archelios CALC 2024

    Thread Starter: nicers

    I have
    PVsyst 8.0.21
    DEHNsupport 3.251
    Archelios CALC 2024
    Exchange for Easypower 2025
    ucv422@gmail.com
    @Nicers236

    Last Post By: nicers 04-13-2026, 08:48 PM Go to last post
  • .

  • ..

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40