Orifice Plate Installed Backwards
by
Published on 03-08-2014 07:36 AM

Originally Posted by
jnunez56
Does anyone have a method to calculate the error introduced by installing an orifice plate backwards for liquid flow?

Originally Posted by
carl_e
Various published studies give errors on the low side over a range of -8 to -25%. But I make no claim of having compiled a comprehensive bibliography on the topic.

Originally Posted by
carl_e