Finally, during some weeks I was working on that topic and there are some conlcutions.
1.Analyze the fluid sampling operation to verify the representative of the fluid.
2.Compare Pressure and temperature conditions of Reservoir and Laboratory.
3.Review the recombination GOR at separator conditions.
4.Verify that operation variables were constant before and after sampling,
5.Confirm Dew point is less than reservoir pressure.
6.Analyze the mathematic recombination (C1-C6 < 2% err) (C7-CX<5% err)
7.Analyze the molar balance (always condensate remain in the cell positive)
8.Verify the linearity of a CVD- Effluent Molecular Composition (EMC Vs Pressure)
9.Confirm all compositions with Hoffman-Cump-Hocott Method SPE-219G