View RSS Feed

Recent Blogs Posts

  1. Reinforcement Calculation for Nozzles on flat plates for an Air Cooled Heat Exchanger

    Quote Originally Posted by Thaksen79 View Post
    Dear Members,

    I would like to know what are the acceptable ways to perform reinforcement calculation on a flat plate for an ASME Sec VIII Div-1 stamp Air Cooled Heat Exchanger. The nozzles sizes are 4" and 8". The flat plate thickness shall be min 10mm.

    Consider the case of Designing an Air Cooled Heat Exchanger. The design parameters are as follows,
    Shell side
    Design Press Int/ext=1.03/FV barg
    Design Temp Int/ext=150/150 deg Celsius
    MDMT= -5
    Corrosion Allow = 0mm

    Tube side
    Design Press Int/ext=0.6/FV barg
    Design Temp Int/ext=90/150 deg Celsius
    MDMT= -5
    Corrosion Allow = 0mm

    The Nozzle sizes approx 4" Outlet and 8" Inlet which are welded to flat plates.

    For more details of the exchanger construction please visit the below link
    https://www.dropbox.com/s/jxat77b0a5...anger.pdf?dl=0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40