Originally Posted by codigo98ii Dear friends of the forum You can share the following API standards published in 2016 - 2017: Recommended Practice 1109 Marking Liquid Petroleum Pipeline Facilities 5th editionRecommended Practice 1133 Guidelines for Onshore Hydrocarbon Pipelines Affecting High Consequence Floodplains 2nd editionRecommended Practice 1160 Managing System Integrity for Hazardous Liquid Pipelines 3rd editionRecommended Practice 1162 Public Awareness Programs for Pipeline Operators 3rd editionStandard 1164 Pipeline SCADA Security 3rd editionRecommended Practice 1177 QMS for New Pipeline Construction 1st edition (http://ballots.api.org/pipeline/ball...allot_3916.pdf)Technical Report 1178 Data Management and Integration Guidelines 1st edition (http://ballots.api.org/pipeline/ball...allot_3935.pdf)Technical Report 1179 Guidelines for Use of Hydrostatic Testing as an Integrity Management Tool 1st edition (http://ballots.api.org/pipeline/TR11...sting_4273.pdf) Thanks Codigo
Originally Posted by CANDICEDALAIS Hi guys* can someone please upload a library of PQR WPS and Welders qualifications for ASME and EN ISO for half inch; 2 inch ; and 6 inch carbon Steel and stainless steel pipe. As well as a few plates that are carbon Steel and stainless steel. Pdf. Would be great.
Originally Posted by Rammohan Check this link. File has been updated. https://www.4shared.com/rar/3lEvcY-D...de_-_Vol1.html Pass: egpet.net This is the 3rd edition* today the download is OK. Thank
See http://www.egpet.net/vb/threads/8850...146#post347146
Dear Mechen* plz re-upload Volume 1 Fourth Edition* the file is corrupted. Thanks in advance.
Originally Posted by Marty Thompson https://telegram.me/joinchat/CfG2TD2yU-dXI2qRkCtqTA Thanks Marty* you are the Leader of an excellent team.
Originally Posted by SHEMYY FRIENDS - TRY THIS SITE - SOME PARTS ARE THERE : https://web.telegram.org/#/im?p=s100...50585449857193 ENJOY . Dear SHEMYY* how i can't see the file on that cloud. How I can see it?
We have been experiencing shallow gas flows (gas broaching) following an abnormal sound in one of the gas wells* since July 2011. This was later identified as a case of underground blowout. One of the contributing factors was erosion of tubing due to sand ingress and annular pressure buildup. Several attempts were made to address the problem by killing the well* drilling of relief well and vent holes* etc. Although the extent of gas flow was contained to a great extent* the same is continuing. The contamination of ground water* fire incidents* etc. are some of the issues that need to be addressed. Complaints of shallow gas flows are reported by people residing in the area neighboring to the well and need to be resolved. Can anyone suggest a remedy to this persistent problem?
Originally Posted by himmelstern there is a video instalation procedure of how to cr.a.ck or pa.tch ETAP 16.0 Friend I need etap 16.1 please tell me how to get it urgently
Hello* I am doing the branch tee reinforcement pad requirement calculation according to EN 13480-3 section 8.4.3. I have some queries as below. (1) In Equation 8.4.3-4 ( lpl <= ls). I have calculated the effective reinforcement of shell pipe (ls) value according to equation 8.4.1-2 which is coming around 190 mm. So According to the equation I can use the reinforcement pad width less than ls means less than 190 mm. If I follow the above equation * it will never satisfy the final equation 8.4.3-6. it seems this equation is not correct. If code restrict the reinforcement pad width how we can satisfy the final equation without increasing the pad width where reinforcement pad width is also limited to eas according to equation 8.4.3-5. Refer attached code page attachment (EN13480-3-Page-82.pdf). Please suggest. (2) EN13480-3 equation 8.4.3-5 condition eapl<=eas shall be satisfy. I am using the reinforcement pad thickness same as shell thickness* means pad will be cut from shell pipe during fabrication. I am using the nominal pad thickness same as shell thickness 16 mm with assuming same corrosion allowances. Refer below calculation. My nominal shell thickness en=16 mm. c0=3.4* c1=0.3 mm.so eas=16-3.4-0.3= 12.3 mm. Plate thickness used enpl=16mm. c0=3.4* c1=0.3 mm. so eapl=12.3 mm. Is my calculation & understanding is correct. As in brief above code restrict the reinforcement pad thickness as well as width to compensate the cutting area for branch. Please find attached my detail calculation. (Terna Reinforcement pad Calculation30052017.pdf)