View Full Version : High pressure steam to reduce into low pressure steam system



achi81
04-15-2010, 07:08 PM
Hello Brothers and friends,

i need urgently a economical solution for reducing high pressure steam line into low pressure steam..

Thank you very much, i appreciate very much

henj
04-16-2010, 06:37 AM
Depending on the amount and pressures of the steam ether a turbine or simple reduction valve..

achi81
04-16-2010, 07:28 AM
Thanks for you reply henj...

The pressure of the steam is around 34 bar, and should be reduced into ~8 bar

henj
04-16-2010, 05:42 PM
Okay - roughly let us then say you get 50 kW electricity per ton steam/h you can calculate your earning and ask a supplier of steam turbines. My guess could be that you shall above 15-20 tons steam/h most of the year to get a good pay back. (not knowing your energy prices). Else chose the reduction valve

henj
04-17-2010, 09:05 AM
Well you may try my small program for turbines yourself:


Preferable if the steam is superheated to say 315 C it would gives ~62 kW/ton/h. Make sure the outlet is superheated T2_SH is a few degrees.

aan09
04-17-2010, 05:34 PM
Hi HENJ ,

MESSAGE APPEAR AT IFILE.IT ....................... file expired
PLS RE UPLOAD

henj
04-17-2010, 08:14 PM
... file expired


I don't know what happened, now I re-upload and corrected the link above. And the link is working now :)

TwistedAngeL
05-21-2011, 06:19 PM
hello everyone =) i'm currently doing my exergy analysis on a power plant for my final year project. i was given a HBD n i did some calculation on d exergy . but it seems like i'm stucked ...need help urgently..plz3...tq

arthur0
07-08-2012, 10:00 PM
learnt something new...thanks

inconel
09-29-2015, 10:25 AM
Thanks for the link.